Start a conversation

Articles

MS Readiness Assessment

  • Syncing the Active Directory Integration Once But Never Again

    Overview When using the AD Integrator with v7.0.3 of the Exinda firmware, it is possible to see that the AD Connector will sync with AD correctly upon an initial connection but then will not sync agai...

  • Meaning of Each of the Acceleration Types Available

    Overview This article provides details on the different types of reductions that you can choose from in a policy. Information When you select Acceleration in a policy, you see a section for WM Reducti...

  • ACPI Warning Logs During Bootup

    Overview A customer may report that while reviewing their logs, the following errors are present: Kernel: ACPI: Warning: 0x00000000000004000-0x000000000000401f SystemIO conflicts with Region \_SB_PCI0...

  • Acceleration Throughput

    Overview This article provides details about the acceleration bandwidth mentioned in the license. Information In license Exinda 3862 (30/20Mbps - HP), max acceleration bandwidth is 20Mbps; and it defi...

  • Acceleration on MAPI Traffic Not Working Due to Misclassification

    Overview Some MAPI users notice that their Outlook Traffic is not being classified as MAPI. If this traffic is not classified as MAPI chances are that if they are attempting to accelerate it, the MAPI...

  • Downloading Large Files and High CPU Usage on Router While Acceleration Is Enabled

    Overview This article provides the details regarding the relation between download file size and CPU usage when acceleration is enabled.  Information When acceleration is enabled, and the Exinda is pr...

  • Acceleration Compatibility Between ExOS Version 6 and 7

    Overview When upgrading firmware from version 6.4.x to 7, there have been some changes made regarding acceleration which could cause incompatibility issues. So, if upgrading devices in stages, it is p...

  • Error: The number of accelerated connections has reached the licensed limit

    Overview An Exinda that has an acceleration license, and has the alert enabled, will sometimes send the following email alert: The number of accelerated connections has reached the licensed limit. Thi...

  • 7.0.2 Release Notes

    Overview This article provides the essential details about the release of 7.0.2 version release.   Environment This release includes all changes from versions up to and including these update releases...

  • 2061 Model Reset Button

    Overview This article provides information about the physical reset button present in the Exinda appliance model 2061. Information There is a button labeled Reset on the back of 2061 model Exinda appl...