Overview
At times, the users are not able to view data/traffic in real time. This article discusses the reason and resolution of this issue.
Root Cause
The probable cause for this issue is one of the following:
- There is no traffic passing through the device through the physical interfaces.
- Traffic is passing through the Exinda but not showing in real-time.
Resolution
To resolve this error, try the following fixes accordingly:
- If the user sees traffic on the interfaces then it means traffic is passing through the Exinda. Just restart processes
collectord
andmonitord
using the following commands:
en
conf t
service collector restart
service monitor restart - If there is no data on the interfaces and the interfaces are up, then possibly traffic is not being routed through the Exinda.
- If the user does not see any link lights and the link is down, then possibly the cables are not connected to the device